COVIDSeq Assay (96 samples)

This low- to mid-throughput NGS assay enables labs of any size to identify and track the emergence and prevalence of novel SARS-CoV-2 variants.

Overview

COVIDSEQ Assay (96 samples) is a comprehensive amplicon-based next-generation sequencing (NGS) assay designed to help research labs identify novel SARS-CoV-2 variants. 

  • Detects genome of SARS-CoV-2 RNA using ARTIC v5.4.2 primers

  • Supports a seamless and flexible end-to-end workflow

Rapid, cost-effective sequencing

Designed to run a low number of samples, the COVIDSeq Assay (96 samples) offers a low-throughput configuration ideal for Illumina benchtop sequencing systems, enabling smaller labs to perform decentralized surveillance of new variants.

Uniform genome coverage

96 amplicons provide full coverage across SARS-CoV-2 genome for in-depth characterization of new variants

Integrated solution

Kit includes all reagents for cDNA conversion, amplification, and library prep. A 63°C annealing temperature during PCR improves variant analysis and insights.

Streamlined data analysis

Assess lineage and annotate mutations with open software tools, including the DRAGEN Microbial Amplicon App in BaseSpace Sequence Hub.

Specifications

Required products

One COVIDSeq Assay (96 samples) is required. There are four options available, all identical except for the included index plate. 

  • Sequencing reagent kit and flow cell for your sequencing system
  • Viral RNA extraction kit (e.g. QIAamp Viral RNA Mini Kit)

The COVIDSeq Positive Control is an optional product.

/ Results

Applications

The COVIDSeq Assay (96 Samples) enables labs using benchtop sequencing systems to perform genomic surveillance of SARS-CoV-2 variants and lineages to identify and monitor new strains.

Example workflow

1
Prep

Illumina COVIDSeq Assay (96 samples)

Related applications and methods

Documentation

Product literature

Compare

COVIDSeq Assay (96 samples) COVIDSeq Test (RUO Version) Respiratory Pathogen ID/AMR Enrichment Panel Kit Pan-Coronavirus Panel
Automation capability Liquid handling robot(s) Liquid handling robot(s) Liquid handling robot(s) Liquid handling robot(s)
Automation details Explore available automation methods Explore available automation methods Explore available automation methods
Content specifications Whole viral genome coverage including the spike protein locus  Whole viral genome coverage including the spike protein locus  Detects respiratory pathogen DNA and RNA simultaneously and profiles antimicrobial resistance (AMR) gene expression concurrently.
Description The COVIDSeq Assay (96 samples) is a low- to mid-throughput NGS assay intended to be processed on any Illumina benchtop sequencing system for research applications. The COVIDSeq Test (RUO Version) is a scalable high-throughput NGS assay (up to 3072 samples) intended for research applications.   Identify respiratory infections and co-infections, detect antimicrobial resistance markers, and perform strain typing of critical pathogens (SARS-CoV-2 and Flu A/B viruses) to study viral evolution and transmission. The Pan-Coronavirus Panel is part of an integrated workflow that allows for the detection and whole-genome sequencing of over 200 known and novel coronavirus strains in various animal hosts.
Instruments MiSeq System, iSeq 100 System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiSeqDx in Research Mode, MiniSeq System, NextSeq 550Dx in Research Mode, NovaSeq 6000Dx in Research Mode, NextSeq 500 System, NovaSeq 6000 System MiSeq System, iSeq 100 System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiSeqDx in Research Mode, MiniSeq System, NextSeq 550Dx in Research Mode, NovaSeq 6000Dx in Research Mode, NextSeq 500 System, NovaSeq 6000 System MiSeq System, NextSeq 550 System, MiniSeq System MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiniSeq System
Method Amplicon sequencing, Targeted RNA sequencing Amplicon sequencing, Targeted RNA sequencing Targeted DNA sequencing, Targeted RNA sequencing, Target enrichment Whole-genome sequencing, Target enrichment
Multiplexing 8-plex on the iSeq System 30–48 plex on the MiSeq System 48-plex on the MiniSeq System 384-plex on NextSeq 384-plex on NovaSeq Up to 384 samples in a single run with unique dual indexes Up to 384 samples in a single run with unique dual indexes
Nucleic acid type RNA RNA DNA, RNA RNA
Sample type details Nasopharyngeal, oropharyngeal, mid-turbinate nasal swab, and wastewater samples Nasopharyngeal, oropharyngeal, mid-turbinate nasal swab, and wastewater samples
Species category Virus Virus Fungal, Virus, Bacteria Virus
Species details SARS-CoV-2 SARS-CoV-2 Detects respiratory pathogens (180+ bacteria, 50+ fungi, and 40+ viruses, including SARS-CoV-2) and antimicrobial resistance alleles (1200+).
Strand specificity Non-stranded Non-stranded Non-stranded
Technology Sequencing Sequencing Sequencing Sequencing

Selection tools:

Figures

Genomic coverage performance

Heat map plotting performance as a function of read length and depth shows significant improvement with paired-end reads over single reads. The fraction of genomes > 0.99 confident is shown, with values close to 1 representing more complete coverage of the SARS-CoV-2 genome.

Library prep (4)

COVIDSeq Assay (96 samples) index 1

20049393

Includes reagents for preparing 96 samples for detection of SARS-CoV-2. Includes index plate 1 with 96 unique dual indexes. Purchase optional positive control and optional v4 primer pools separately

Sign in to add to cart or see pricing.

List Price:

Discounts:

COVIDSeq Assay (96 samples) index 2

20051772

Includes reagents for preparing 96 samples for detection of SARS-CoV-2. Includes index plate 2 with 96 unique dual indexes. Purchase optional positive control and optional v4 primer pools separately

Sign in to add to cart or see pricing.

List Price:

Discounts:

COVIDSeq Assay (96 samples) index 3 RUO

20051773

Includes reagents for preparing 96 samples for detection of SARS-CoV-2. Includes index plate 3 with 96 unique dual indexes. Purchase optional positive control and optional v4 primer pools separately

Sign in to add to cart or see pricing.

List Price:

Discounts:

COVIDSeq Assay (96 samples) index 4 RUO

20051774

Includes reagents for preparing 96 samples for detection of SARS-CoV-2. Includes index plate 4 with 96 unique dual indexes. Purchase optional positive control and optional v4 primer pools separately

Sign in to add to cart or see pricing.

List Price:

Discounts:

Accessory products (2)

COVIDSeq Positive Control

20051775

Includes 100 uL of COVIDSeq Positive Control to support quality control

Sign in to add to cart or see pricing.

List Price:

Discounts:

Illumina COVIDSeq v4 Primer Pools, 384 Samples RUO

20065135

Includes optional ARTIC v4 primer pools reagents sufficient for up to 384 samples. Replaces v3 primer pools included in the COVIDSeq Test (RUO) and COVIDSeq Assay (96 samples).

Sign in to add to cart or see pricing.

List Price:

Discounts:

Showing of

Selection summary

Product

Qty

Unit Price

FAQs

The primary difference is the number of samples each assay can run. The COVIDSeq Assay (96 samples) runs up to 96 samples on Illumina benchtop sequencing systems to accommodate smaller research labs. In contrast, the COVIDSeq Test (RUO) runs up to 3072 samples on the NovaSeq 6000 System or NextSeq line of sequencing systems.

Prepared libraries can be sequenced on any Illumina sequencing system. However, the low-throughput configuration of the COVIDSeq Assay (96) samples is ideal for Illumina benchtop sequencing systems, including the iSeq 100, MiniSeq, MiSeq, NextSeq 550, NextSeq 1000, and NextSeq 2000 Systems.

As SARS-CoV-2 mutates, updates to the primer pools are occasionally necessary to ensure complete coverage across the genome and improved analytical sensitivity for SARS-CoV-2 variant detection. The v5.4.2 primers provide increased coverage for recent Omicron variants.

/ Results

Order the NovaSeq X Series

Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.

MiSeq Reagent Kit v3

Optimized reagent kit that provides increased cluster density and read length, improving sequencing quality scores compared to earlier versions.

TruSight Oncology 500

Enable CGP with a large pan-cancer panel covering all major variant classes plus gene signatures (TMB, MSI, and HRD) from FFPE tissue.

Illumina DNA Prep

A fast, integrated workflow for preparing libraries for use in a wide range of sequencing applications.

COVIDSeq Test (RUO Version)

This high-throughput NGS assay enables labs to detect SARS-CoV-2 mutations to identify and track the emergence and prevalence of novel variants.

Speak with a specialist

Reach out for information about our products and services, or get answers to questions about our technology.