Order the NovaSeq X Series
Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.
Targeted RNA research panel to investigate T cell diversity and clonal expansion by sequencing T cell receptor beta chain rearrangements.
Assay time
Hands-on time
AmpliSeq for Illumina Immune Repertoire Plus, TCR beta Panel is a highly multiplexed targeted resequencing panel to measure T cell diversity and clonal expansion by sequencing T cell receptor (TCR) beta chain rearrangements. Use a single pool of multiplex PCR primers, library reagents, and sample barcodes, to generate libraries from RNA extracted from whole blood, fresh-frozen tissue, or FACS-sorted cells.
The Immune Repertoire Plus, TCR beta Panel is part of an integrated workflow that includes AmpliSeq for Illumina polymerase chain reaction (PCR)-based library preparation, Illumina sequencing by synthesis (SBS), NGS technology, and automated analysis.
This ready-to-use panel saves you the time and effort of identifying targets, designing primers, and optimizing panels.
Assay time | 5.5 – 7.5 hours (library prep only; doesn't include library quantification, normalization, or pooling time) |
---|---|
Content specifications | RNA evaluation of TCRβ chain rearrangements, including CDR1, CDR2, and CDR3 (with up to 400 bp read-length amplicons) |
Hands-on time | < 1.5 hr |
インプット量 | 10~1,000 ng |
Instruments | MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiniSeq System |
Mechanism of action | Multiplex PCR |
Method | Amplicon sequencing, Targeted RNA sequencing |
Multiplexing | 96 dual index combinations |
Nucleic acid type | RNA |
Sample type details | Libraries can be generated from RNA extracted from whole blood, fresh/frozen tissue, or fluorescence-activated cell sorting (FACS)-sorted cells. |
Specialized sample types | Blood |
Species category | Human |
Technology | Sequencing |
Variant class | Transcript variants |
The AmpliSeq for Illumina Immune Repertoire Plus, TCR beta Panel workflow requires the Immune Response Panel oligos, one of the AmpliSeq Library PLUS kits, an AmpliSeq cDNA Synthesis kit, and at least one AmpliSeq index kit.
AmpliSeq for Illumina Immune Repertoire Plus, TCR beta Panel
Instrument | Recommended number of samples | Read length |
---|---|---|
MiniSeq System | Samples per run will depend on sample type. |
2 × 150 bp |
MiSeq System | Samples per run will depend on sample type. |
2 x 300 bp |
NextSeq 550 System | Samples per run will depend on sample type. |
2 × 150 bp |
With targeted resequencing, a subset of genes or a genomic region is isolated and sequenced, which can conserve lab resources.
Illumina NGS and microarray technologies for cancer research are helping drive the revolution in cancer genomics.
Gain insight into the immune repertoire, disease mechanisms, and the functional impact of immune-related genetic variation with NGS and array solutions.
AmpliSeq for Illumina Immune Repertoire Plus, TCR beta Panel | AmpliSeq for Illumina TCR beta-SR Panel | |
---|---|---|
Assay time | 5.5 – 7.5 hours (library prep only; doesn't include library quantification, normalization, or pooling time) | 5.5~7.5時間(時間はライブラリー調製のみを表し、ライブラリー定量、ノーマライゼーション、プーリングは含まない) |
Content specifications | RNA evaluation of TCRβ chain rearrangements, including CDR1, CDR2, and CDR3 (with up to 400 bp read-length amplicons) | Sequences TCR beta chain rearrangements, with up to 80 bp read-length amplicons for characterizing CDR3. |
Hands-on time | < 1.5 hr | <1.5 hr |
インプット量 | 10~1,000 ng | 1 ng |
Instruments | MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiniSeq System | MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiniSeq System |
Mechanism of action | Multiplex PCR | Multiplex PCR |
Method | Amplicon sequencing, Targeted RNA sequencing | Targeted DNA sequencing, Amplicon sequencing, Targeted RNA sequencing |
Nucleic acid type | RNA | DNA, RNA |
Sample type details | Libraries can be generated from RNA extracted from whole blood, fresh/frozen tissue, or fluorescence-activated cell sorting (FACS)-sorted cells. | |
Specialized sample types | Blood | Blood, FFPE tissue |
Species category | Human | Human |
Technology | Sequencing | Sequencing |
Variant class | Transcript variants | Transcript variants |
AmpliSeq™ for Illumina® Immune Repertoire Plus, TCR beta Panel
20024479
Sufficient for 24 reactions when paired with AmpliSeq Library PLUS for Illumina. Purchase library prep, index adapters, and accessory products separately.
List Price:
Discounts:
AmpliSeq™ Library PLUS (24 Reactions) for Illumina®
20019101
Includes reagents for preparing 24 libraries. Purchase AmpliSeq for Illumina panel and index adapters separately.
List Price:
Discounts:
AmpliSeq™ Library PLUS (96 Reactions) for Illumina®
20019102
Includes reagents for preparing 96 libraries. Purchase AmpliSeq for Illumina panel and index adapters separately.
List Price:
Discounts:
AmpliSeq™ Library PLUS (384 Reactions) for Illumina®
20019103
Includes reagents for preparing 384 libraries. Purchase AmpliSeq for Illumina panel and index adapters separately.
List Price:
Discounts:
AmpliSeq™ UD Indexes for Illumina® (24 Indexes, 24 Samples)
20019104
Includes 24 indexes sufficient for labeling 24 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
AmpliSeq™ CD Indexes Set A for Illumina®
20019105
Includes 96 indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
AmpliSeq™ CD Indexes Set B for Illumina®
20019106
Includes 96 indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
AmpliSeq™ CD Indexes Set C for Illumina®
20019107
Includes 96 indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
AmpliSeq™ CD Indexes Set D for Illumina®
20019167
Includes 96, 8 bp indexes sufficient for labeling 96 samples. Purchase library prep reagents and probe panels separately.
List Price:
Discounts:
AmpliSeq™ CD Indexes Set A-D for Illumina® (384 Indexes, 384 Samples)
20031676
Includes four sets of AmpliSeq CD Indexes for Illumina, Set A, Set B, Set C and Set D. Each set contains 96, 8 bp indexes sufficient for labeling 96 samples. Purchase library prep and probe panels separately.
List Price:
Discounts:
Ampliseq™ cDNA Synthesis for Illumina®
20022654
Includes reaction mix and enzyme blend to convert total RNA to cDNA when working with AmpliSeq for Illumina RNA Panels (eg, AmpliSeq for Illumina Immune Response, Immune Repertoire Plus, TCR beta Panel, Myeloid, Transcriptome Human Gene Expression, Focus, and Comprehensive Panel v3 as well as Custom or Community RNA Panels). Number of reactions vary by panel (eg, 100 reactions per kit for AmpliSeq for Illumina Immune Response, Focus, Comprehensive Panel v3, and Custom panels and 200 reactions per kit for AmpliSeq for Illumina Transcriptome Human Gene Expression, Myeloid, Immune Repertoire Plus, and TCR beta Panels).
List Price:
Discounts:
AmpliSeq™ Library Equalizer for Illumina®
20019171
Includes beads and reagents for library normalization when preparing AmpliSeq for Illumina libraries for sequencing.
List Price:
Discounts:
Showing of
Product
Qty
Unit Price
Product
Catalog ID
Quantity
Unit price
Reach out for information about our products and services, or get answers to questions about our technology.
Your email address is never shared with third parties.