Pillar oncoReveal Myeloid Panel

A targeted NGS research assay testing 58 key genes relevant to myeloid malignancies.

< 8 hr assay time; < 24 hr sample to result

Assay time

~3-5 hr

Hands-on time

10-80 ng (20-60 ng recommended)

Input quantity

See full details in the specifications table

Overview

The Pillar Biosciences oncoReveal Myeloid Panel is a next-generation sequencing (NGS) research assay designed to interrogate 58 genes relevant to myeloid malignancies. The panel uses proprietary Stem-Loop Inhibition Mediated amplification (SLIMamp) technology, a tiled amplicon-based library prep chemistry, for efficient single-tube target enrichment.

Key features

  • Access a rapid workflow to go from sample to result in under 24 hours

    This library prep kit requires limited hands-on time and can be run on the MiSeq i100 Series for our fastest sequencing time yet.

  • Achieve variant detection below 5% even with limited DNA input or suboptimal sample quality

    SLIMamp enrichment chemistry uses overlapping multiplex PCR for effective target capture in a single tube requiring less sample input to deliver reliable results.

  • Improve lab efficiency by reducing 'no calls' and repeat testing to simplify data interpretation

    Innovative targeting chemistry with trusted Illumina sequencing and analysis come together to provide reliability from sample to result.

Specifications

Required Products

Pillar Biosciences oncoReveal panels require the use of a Pillar index kit and sequencing reagents. DRAGEN Amplicon software is recommended for secondary analysis.

/ Results

Applications

Example workflow

Documentation

Product literature

Compare

Pillar oncoReveal Myeloid Panel Pillar oncoReveal Essential MPN Panel Pillar oncoReveal Heme Fusion Panel
Assay time < 8 hr assay time; < 24 hr sample to result < 8 hrs assay time; < 24 hrs sample to result < 11 hr assay time (including reverse transcription); as fast as < 24 hr from sample to result
Cancer type Hematologic Hematologic Pan-cancer, Hematologic
Content specifications Full CDS coverage of 18 genes plus hotspots on 40 additional genes including FLT3-ITDs CALR (exon 9), JAK2 (exon 12-15), MPL (exon 10) 39 driver genes with >50 fusion partners covering 295 fusion events plus KMT2A partial tandem duplications (PTDs)
Description This NGS research assay analyzes 58 genes relevant to myeloid malignancies This NGS targeted research assay analyzes six exons from three genes relevant to myeloproliferative neoplasm (MPN) conditions This NGS targeted research assay analyzes RNA for gene fusions, expression imbalances, and other rearrangements
Hands-on time ~3-5 hr ~3-5 hr ~3-5 hr
Input quantity 10-80 ng (20-60 ng recommended) 10-80 ng (20-60 ng recommended) 40 ng RNA
Instruments MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiSeqDx in Research Mode, NextSeq 550Dx in Research Mode, MiSeq i100 Plus System, MiSeq i100 System MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiSeqDx in Research Mode, NextSeq 550Dx in Research Mode, MiSeq i100 Plus System, MiSeq i100 System MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiSeqDx in Research Mode, NextSeq 550Dx in Research Mode, MiSeq i100 Plus System, MiSeq i100 System
Mechanism of action Multiplex PCR using tiled amplicon Multiplex PCR using tiled amplicon Multiplex PCR using tiled amplicon
Method Targeted DNA sequencing, Amplicon sequencing Targeted DNA sequencing, Amplicon sequencing Amplicon sequencing, Targeted RNA sequencing
Nucleic acid type DNA DNA RNA
Number of amplicons 1 pool, 766 amplicons 1 pool, 7 amplicons 1 pool, > 50 amplicons
Number of reactions 24 reactions 48 reactions per kit 24 reactions per kit
On-target reads 98.7 +/- 0.4% 99.7 +/- 0.2%
Specialized sample types Blood, Low-input samples Blood, Low-input samples Blood, Low-input samples, Bone marrow
Species category Human Human Human
Target insert size 217 bp 225 bp 204 bp
Technology Sequencing Sequencing Sequencing
Uniformity 96.4% +/- 2.1% 100%
Variant class Single nucleotide variants (SNVs), Insertions-deletions (indels), Copy number variants (CNVs) Somatic variants, Single nucleotide variants (SNVs), Insertions-deletions (indels)

Figures

Gene List

Gene list

Pillar oncoReveal Myeloid Panel interrogates 58 genes from DNA.

Panel Specifications

Panel specifications

Pillar oncoReveal Myeloid Panel specifications table.

Resources

Thumbnail

Accelerating targeted oncology research

Dr Francine de Oliveira, medical pathologist and coordinator of the Genetics and Molecular Biology Laboratory at Moinhos de Vento Hospital in Brazil discusses how her team uses targeted panels for oncology research.

oncoReveal Myeloid Panel

HDA-MY-1001-24

oncoReveal™ Myeloid Panel

Sign in to add to cart or see pricing.

List Price:

Discounts:

Indices PI501-8, PI701-4 (32 combinations, 96 reactions)

IDX-PI-1001-96

Indices PI501-8, PI701-4 (32 combinations, 96 reactions)

Sign in to add to cart or see pricing.

List Price:

Discounts:

Kit D, indices PI501-8, PI701-12

IDX-PI-1004-192

Kit D, indices PI501-8, PI701-12

Sign in to add to cart or see pricing.

List Price:

Discounts:

Showing of

Selection summary

Product

Qty

Unit price

MiSeq i100 Series ordering

Simplified operations, advanced chemistry, and onboard informatics provide an easy-to-use, fast, and flexible instrument supporting a broad range of applications.

MiSeq i100 Series Reagent Kits

Reagents for the MiSeq i100 Series feature easy-to-use cartridges and multiple flow cell configurations for flexible sequencing options.

TruSight RNA Fusion Panel

Comprehensive gene fusion detection covering 507 genes from FFPE and other cancer research samples.

TruSight RNA Pan-Cancer Panel

Target 1385 cancer genes for gene expression, variant, and fusion detection studies in many RNA sample types, including blood, bone marrow, and FFPE tissue.

Speak with a specialist

Reach out for information about our products and services, or get answers to questions about our technology.